• Tutorials

    TUTORIALS

    To evaluate soluble salts present on metallic surfaces, use the TQC Sheen Bresle Kit SP7310 together with the Bresle patch and the digital conductivity meter supplied in the kit.

    The test allows soluble contaminants present within a defined surface area to be extracted and the conductivity of the resulting solution to be measured. The result helps verify surface cleanliness before the application of protective coatings.

    Before testing, make sure that all components used are clean and that the conductivity meter has been properly checked or calibrated according to the manufacturer's instructions.

  • Function details

    FUNCTION DETAILS

    Soluble salt evaluation
    The kit allows the evaluation of soluble ionic contaminants on metallic surfaces before the application of paint systems and protective coatings.

    Bresle extraction method
    Uses Bresle patches to define a surface area and enable the extraction of soluble salts using distilled water.

    Digital conductivity meter
    The instrument supplied with the kit measures the conductivity of the solution extracted from the surface, enabling evaluation of soluble salt contamination.

    Surface preparation control
    Helps identify contaminants that may remain on the substrate even after cleaning and mechanical or abrasive blasting surface preparation processes.

    Prevention of coating failures
    Checking surface contamination helps control substrate conditions before painting, reducing risks associated with excessive soluble salts beneath the coating.

    Complete inspection kit
    The kit includes the main components required to perform the test in the field, including a digital conductivity meter, Bresle patches, containers, syringe, distilled water, and solutions for checking the instrument.
  • Applications

    APPLICATIONS

    Evaluation of soluble salts on metallic surfaces;
    Surface cleanliness control before painting;
    Inspection of surfaces prepared by abrasive blasting;
    Conductivity measurement of solutions extracted from the surface;
    Surface contamination control on steel structures;
    Quality control in industrial coating processes;
    Surface evaluation before application of primers and protective coatings;
    Industrial, marine, offshore and steel structure maintenance;
    Training and qualification of coating and inspection professionals.

    Recommended for coating inspectors, corrosion professionals, surface preparation companies, quality control teams, service providers, shipyards, maintenance companies and industries that need to evaluate soluble salt contamination before coating application.

  • Technical data

    TECHNICAL DATA:

    Product TQC Sheen Bresle Kit
    Reference SP7310
    Manufacturer SKU SP7310-1
    Type Kit for soluble salt evaluation using the Bresle method
    Evaluation principle Extraction of soluble contaminants and conductivity measurement
    Application Coating inspection and corrosion control
    Materials Metals, paints and coatings
    Measuring instrument Digital conductivity meter
    Bresle patches 25 units
    Beakers 6 units of 25 ml
    Distilled water 200 ml
    Syringe 20 ml with needle
    Supplied solutions Calibration solution and rinse solution
    Marking accessory Magnetic marker for Bresle test point
    Purpose Evaluation of soluble salt contamination before coating application
  • Documents

    DOCUMENTS

    The TQC Sheen Bresle Kit SP7310 is intended for evaluating soluble salts present on surfaces by extracting contaminants with a Bresle patch and subsequently measuring the conductivity of the resulting solution.

    The manufacturer provides product-related documentation, including a Declaration of Conformity and Calibration Certificate.
  • Replacement parts

    REPLACEMENT PARTS

    Bresle patches and other consumables used during testing should be replaced as required and according to the number of tests performed. Contact WS Equipamentos for availability of Bresle patches, solutions, accessories and instruments for soluble salt evaluation and surface inspection.