To perform soluble salt contamination testing, position the PosiPatch system on the metallic surface using the rigid magnetic ring to keep the patch properly secured and sealed throughout the procedure.
Introduce the extraction solution into the PosiPatch according to the applicable test procedure, allowing the soluble salts present within the defined area to dissolve. After extraction, the solution can be analyzed using a compatible conductivity meter and probe.
The reusable system eliminates the need for traditional adhesive patches and prevents adhesive residue from remaining on the surface after testing. The rigid ring is especially suitable for flat surfaces or surfaces with large diameters.
Soluble salt contamination testing;
Contaminant extraction using the Bresle method;
Surface evaluation before painting;
Inspection of metallic surfaces prepared by abrasive blasting;
Quality control in surface preparation;
Inspection of metallic structures;
Testing on flat surfaces or surfaces with large diameters;
Field and laboratory inspections;
Contamination control before the application of protective coatings;
Testing according to procedures related to ISO 8502-6 and ISO 8502-9.
Recommended for coating inspectors, corrosion professionals, surface preparation companies, quality control teams, shipyards, service providers and industries that need to evaluate the presence of soluble salts before coating application.
TECHNICAL DATA:
| Product | PosiPatch SST Starter Kit – Rigid Ring |
| Type | Soluble salt testing kit |
| Method | Soluble salt extraction using the Bresle method |
| System | Reusable PosiPatch |
| Ring type | Rigid magnetic ring (Standard) |
| Recommended surfaces | Flat metallic surfaces or surfaces with large diameters |
| Attachment | Magnetic |
| Adhesive | No adhesive required for system attachment |
| Measurement | Use with compatible conductivity meter and probe |
| Extraction standard | ISO 8502-6 |
| Salt determination | ISO 8502-9 |
| Application | Evaluation of soluble salt contamination on surfaces |
| Use | Field and laboratory |
| Benefit | Reusable system with no adhesive residue and high test repeatability |
| Purpose | Control of surface contamination before coating application |
To perform soluble salt contamination testing, position the PosiPatch system on the metallic surface using the rigid magnetic ring to keep the patch properly secured and sealed throughout the procedure.
Introduce the extraction solution into the PosiPatch according to the applicable test procedure, allowing the soluble salts present within the defined area to dissolve. After extraction, the solution can be analyzed using a compatible conductivity meter and probe.
The reusable system eliminates the need for traditional adhesive patches and prevents adhesive residue from remaining on the surface after testing. The rigid ring is especially suitable for flat surfaces or surfaces with large diameters.
Soluble salt contamination testing;
Contaminant extraction using the Bresle method;
Surface evaluation before painting;
Inspection of metallic surfaces prepared by abrasive blasting;
Quality control in surface preparation;
Inspection of metallic structures;
Testing on flat surfaces or surfaces with large diameters;
Field and laboratory inspections;
Contamination control before the application of protective coatings;
Testing according to procedures related to ISO 8502-6 and ISO 8502-9.
Recommended for coating inspectors, corrosion professionals, surface preparation companies, quality control teams, shipyards, service providers and industries that need to evaluate the presence of soluble salts before coating application.
TECHNICAL DATA:
| Product | PosiPatch SST Starter Kit – Rigid Ring |
| Type | Soluble salt testing kit |
| Method | Soluble salt extraction using the Bresle method |
| System | Reusable PosiPatch |
| Ring type | Rigid magnetic ring (Standard) |
| Recommended surfaces | Flat metallic surfaces or surfaces with large diameters |
| Attachment | Magnetic |
| Adhesive | No adhesive required for system attachment |
| Measurement | Use with compatible conductivity meter and probe |
| Extraction standard | ISO 8502-6 |
| Salt determination | ISO 8502-9 |
| Application | Evaluation of soluble salt contamination on surfaces |
| Use | Field and laboratory |
| Benefit | Reusable system with no adhesive residue and high test repeatability |
| Purpose | Control of surface contamination before coating application |