    TUTORIALS

    For correct measurements, apply a small amount of ultrasonic couplant gel to the surface being measured. Place the 200 C probe firmly at the measurement point and wait for the reading. In Advanced C3 mode, use the graphical display to view and analyze up to three individual layers of the coating system. Repeat measurements at different points for greater result reliability.

    BAIXAR TUTORIAL
  • Function Details

    FUNCTION DETAILS

    Non-destructive ultrasonic measurement
    Measures the thickness of coatings applied to non-metallic substrates without damaging the system.

    Advanced C3 model – multiple layers
    Capable of measuring total thickness and up to 3 individual layers with detailed graphical display.

    Ready to use
    Requires no calibration for most applications, simplifying field and laboratory use.

    2.8" color touchscreen
    Intuitive, impact-resistant interface with fast and clear navigation.

    Interchangeable PosiTector platform
    Compatible with various probes in the PosiTector line, expanding equipment versatility.

    Advanced connectivity
    Integrated USB, Wi-Fi and Bluetooth with PosiSoft software for PC, Mac and mobile devices.
  • Applications

    APPLICATIONS

    Coating thickness measurement on non-metallic substrates
    Quality control in multilayer coating systems
    Non-destructive inspection on concrete, wood, plastics and composites
    Evaluation of industrial floors, membranes, paints and sealants

    Recommended for inspectors, engineers, industrial coating teams, maintenance and quality control.

  • Technical Data

     

    TECHNICAL DATA:

    Type Ultrasonic coating thickness gauge
    Model PosiTector 200C3 (Advanced)
    Measurement technology Ultrasonic
    Typical measurement range 50 to 3800 µm (2 to 150 mils)
    Layer capability Total thickness and up to 3 individual layers
    Compatible substrates Concrete, wood, plastic, fiberglass and non-metallic materials
    Enclosure protection IP65 – water and dust resistant
    Compatible standards ASTM D6132 and ISO 2808